Compatible Fluids
|
Water and ethylene glycol aqueous solutions (viscosity ≤3mPa·s 〔3cP〕)
|
|---|---|
|
Detection Method
|
Kármán vortex street type
|
|
Fluid Temperature
|
0~90℃ (non-freezing/non-condensing)
|
|
Accuracy
|
Display: ±3%F.S., Analog output: ±3%F.S.
|
|
Repeatability
|
±2%F.S. |
|
Operating Pressure Range
|
0~1MPa |
|
Pressure Loss(without flow control valve)
|
≤45kPa at max flow
|
|
Certifications
|
CE、UL |
|
Protection class
|
IP65 |